The Isolated Multi-channel DAQ for Multi-cell Stack Systems is a compact unit developed and packaged for retro fit installation in fuel-cell stack and for similar systems. The system facilitates monitoring of voltage across all proton exchange membranes with programmable alarms, temperature of stack at various points, control of hydrogen flow through the stack, power control and alarms. The system also offers touch screen local GUI along with PC based interface. The system can also have extended access over Modbus RTU to SCADA mainstream software. The equipment shall be an import substitute to a high density programmable modular DAQ system.
The 'Isolated Multi-channel DAQ for Multi-cell Stack system' is a compact unit developed and packaged for retro fit installation in fuel-cell stack and for similar systems. The system facilitates monitoring of voltage across all proton exchange membranes with programmable alarms, temperature of stack at various points, control of hydrogen flow for power control etc. The system also offers touch screen based local GUI along with PC based control interface. The system is also compatible with open-source SCADA platforms.
The Isolated Multi-channel DAQ for Multi-cell Stack Systems is a compact retro fit unit designed and developed for installation in the fuel-cell and for similar systems. The system facilitates monitoring of voltage across all proton exchange membranes with programmable alarms, temperature profile of stack, power monitoring, control of hydrogen flow through the stack etc. The system also offers touch screen based local GUI along with PC based control interface. The system can also be extended over Modbus RTU to most of the mainstream SCADA software. The equipment shall be an import substitute to a high density programmable modular DAQ system.
Potential application areas of the system are:
This standalone system provides 30 isolated analog input channels for monitoring of proton membrane voltages and power monitoring and control by controlling hydrogen flow rate. The system also provides acquisition channels for 8 thermocouple points for fuel cell stack temperature monitoring at various points. The system has inbuilt discreet input/output control for external hydrogen LEL trip sensors and alarms. The data is monitored on a touchscreen enabled GUI locally as well as a PC interface software. This entire system is packed in a retrofit unit of dimensions 8 X 8 X 2 (L x W x H in inches).
I. Input: 12 + 1 V DC
II. Current consumption:
III. Analog signal specification:
IV. Discreet channel:
V. Compliance:
VI. Display:
VII. Dimension: 8 X 8 X 2 (L x W x H in inches)
VIII. Weight: 600 Gms
The following facilities are required for the production if the system:
N.B. The vendor does not need to own the facilities like PCB fabrication and enclosure fabrication, as these can be outsourced